companydirectorylist.com  वैश्विक व्यापार निर्देशिकाएँ और कंपनी निर्देशिकाएँ
खोज व्यवसाय , उद्योग, कंपनी :


देश सूचियाँ
संयुक्त राज्य अमेरिका कंपनी निर्देशिकाएँ
कनाडा व्यापार सूचियाँ
ऑस्ट्रेलिया व्यापार निर्देशिका
फ्रांस कंपनी सूची
इटली कंपनी सूचियाँ
स्पेन कंपनी निर्देशिका
स्विटज़रलैंड व्यवसाय सूची
ऑस्ट्रिया कंपनी निर्देशिका
बेल्जियम व्यापार निर्देशिका
हांगकांग कंपनी सूचियाँ
चीन व्यापार सूचियाँ
ताइवान की कंपनी सूचियाँ
संयुक्त अरब अमीरात कंपनी निर्देशिकाएँ


उद्योग कैटलॉग
संयुक्त राज्य अमेरिका उद्योग निर्देशिकाएँ














  • NC Garage Legal Finish Requirement | The Building Code Forum
    The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
  • Step from garage into House?? - The Building Code Forum
    I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
  • Equipment Bollard in a Residential Garage - The Building Code Forum
    Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
  • Minimum Floor Slope for Drainage - The Building Code Forum
    Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
  • 2024 Portal Frames | The Building Code Forum
    In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
  • fire separation in garages - The Building Code Forum
    When constructing split entry's, we alway's framed around the steel I-beam and post in the garage, installed gyp and taped the seams Same on the fur-down (duct covering)and ceiling gyp, just tape unless spray texure was being installed, alway's thought that was the code are we requiring something different now?
  • Garage with no windows doors? | The Building Code Forum
    Garage has stairs into house above Do I need to provide a door and or window in the garage? Garage has overhead coiling door
  • Garage Floor Drain - The Building Code Forum
    Needing some info on garage floor drain Have read codes that garage floor must slope out or to a drain Have new residential construction with attached garage The builder installed what he identifies as floor drain I drained the livewell from my boat in garage floor Floor is completely




व्यापार निर्देशिकाएँ , कंपनी निर्देशिकाएँ
व्यापार निर्देशिकाएँ , कंपनी निर्देशिकाएँ copyright ©2005-2012 
disclaimer